CE-4008-20V10A
20V10A charge/discharge battery testing system, efficient and precise for 3C battery testing.
Quantity
Key Highlights
8 independent channels for parallel battery testing
Voltage output: 0.1–20 V
Current output: up to 10 A
Single-channel output power: 200 W
Voltage & current accuracy: ±0.02% F.S.
Voltage stability: 0.1% F.S.
Current stability: 0.04% F.S.
Current response time: ≤1 ms
Charge/discharge switching time: ≤10 ms
Minimum pulse width: 100 ms
Recording frequency: 10 Hz
AD/DA resolution: 24-bit / 16-bit
Energy efficiency: >70%
DCIR testing supported
Supports CC, CV, CP, CR, and pulse charge/discharge
Up to 32 pulses per step
4-wire connection for reducing line-loss measurement errors
TCP/IP communication, with optional CAN / RS485 for BMS communication
Long-duration testing up to 365 × 24 hours per step
Description
The NEWARE CE-4008-20V10A is an 8-channel battery testing system designed for high-precision battery characterization, 3C battery testing, and long-duration charge-discharge evaluation. With a voltage range of 0.1–20 V, current output up to 10 A, and 200 W output power per channel, it provides greater voltage capability than many conventional 5 V battery testers. The system supports multiple operating modes including CC, CV, CP, CR, and pulse charge-discharge, as well as DCIR testing. Its ≤1 ms current response and ≤10 ms charge-discharge switching time make it suitable for dynamic battery testing and pulse-based measurements. With ±0.02% F.S. voltage and current accuracy, 24-bit AD resolution, 4-wire measurement, and >70% energy efficiency, the CE-4008-20V10A is designed for reliable and efficient battery testing in research and laboratory environments.
Specifications
Parameter | Specification |
Model | CE-4008-20V10A |
Series | CE-4000 |
Number of Channels | 8 independent channels |
Voltage Output Range | 0.1–20 V |
Minimum Discharge Voltage | 2 V (2 m wire length) |
Voltage Accuracy | ±0.02% F.S. |
Voltage Stability | 0.1% F.S. |
Current Output | Up to 10 A |
Current Accuracy | ±0.02% F.S. |
Current Stability | 0.04% F.S. |
Minimum Output Current | 0.5% F.S. per independent range |
CV Cut-off Current | 0.2% F.S. per independent range |
Single-Channel Output Power | 200 W |
Power Accuracy | ±0.07% F.S. |
Power Stability | 0.14% F.S. |
Current Response Time | ≤1 ms |
Charge/Discharge Switching | ≤10 ms |
Minimum Pulse Width | 100 ms |
Pulse Capability | Up to 32 pulses per step |
Recording Frequency | 10 Hz |
AD Resolution | 24-bit |
DA Resolution | 16-bit |
Energy Efficiency | >70% |
Communication | TCP/IP; optional CAN, RS485 |
Connection | 4-wire connection |
Input Power | 2300 W |
Operating Temperature | 0–40°C |
Storage Temperature | −10–50°C |
Noise Level | <75 dB at 1 m |
Safety Protection | Over-voltage, over-current, reverse connection, over-temperature, emergency stop |
Long-Term Test Duration | Up to 365 × 24 h per step |
Application
3C Battery Testing
Battery Cell Characterization
Rechargeable Battery Testing
Battery Materials Research
Charge/Discharge Testing
Cycle Life Testing
DCIR Testing
Pulse Charge/Discharge Testing
Battery Aging & Long-Term Testing
Battery Performance Evaluation
BMS Communication & Testing
Laptop and Tablet Batteries
Portable Electronics
Battery Development & R&D