Andromeda X
Screen and optimize expression conditions for your toughest recombinant proteins.
Quantity
Key Highlights
Analyze protein expression and thermal stability in crude lysates
No protein purification required before measurement
Screen up to 48 samples in under 15 minutes
Uses only 10 µL of lysate per measurement
Highly sensitive spectral shift optics for detecting low-expression proteins
Provides information on both protein expression level and folding/stability
Perform in-lysate thermal shift assays to evaluate protein functionality and ligand binding
Compatible with lysates from E. coli, HEK293, and Sf9 expression systems
Can also analyze cell culture supernatants containing secreted proteins
Site-specific labeling options are available for His-tagged, SNAP-tagged, biotinylated, and human Fc-tagged proteins
Description
Andromeda X is a protein expression and stability analysis system designed to help researchers evaluate recombinant proteins before purification. By working directly with crude lysates, the system provides information on protein expression, folding, and thermal stability without requiring a purification step. Andromeda X uses highly sensitive Spectral Shift optics to selectively monitor the target protein during a temperature ramp. Changes in fluorescence are used to determine the inflection temperature (Ti), helping researchers compare expression conditions, identify stable protein constructs, and evaluate ligand-induced stabilization. With a low sample requirement of 10 µL and the ability to screen up to 48 samples in under 15 minutes, Andromeda X can help researchers identify promising protein constructs and expression conditions early in the workflow.
Specifications
Measurement technology: Spectral Shift Sample type: Crude lysates, cell culture supernatants Sample volume: 10 µL per measurement Sample purification: Not required Maximum samples per run: 48 samples Measurement time: Less than 11 minutes for 48 samples at maximum heating rate Typical total workflow: About 15 minutes, including labeling and measurement Maximum heating rate: 7.0°C/min Main output: Inflection temperature (Ti), fluorescence signal / expression-related information Detection: Fluorescence at 650 nm and 670 nm Expression systems: E. coli, HEK293, Sf9 Labeling options: His-tag, SNAP-tag, biotinylated, human Fc Analysis software: AN.Control / AN. Stability Analysis
Application
Recombinant protein expression screening
Protein stability analysis
In-lysate thermal shift assays
Protein construct screening
Expression condition optimization
Pre-purification quality assessment
Protein folding analysis
Ligand binding / functionality assessment
Antibody fragment screening
Membrane protein detergent screening
Protein engineering
Biopharmaceutical research
Early-stage protein characterization