top of page

CT-9000-5V15A

4 ranges, wide dynamic range, high-speed sampling, and high accuracy.

Quantity

Key Highlights

  • 4 selectable current ranges: 0.015 mA–15 mA, 15 mA–150 mA, 150 mA–1.5 A, and 1.5 A–15 A

  • 0–5 V output per channel

  • Up to 15 A current per channel

  • ±0.02% F.S. voltage and current accuracy

  • ±0.01% F.S. stability

  • 1,000 Hz data recording frequency

  • ≤150 μs current response time

  • 400 μs minimum pulse width

  • 75 W output power per channel

  • 16-bit AD resolution

  • 1 GB offline test storage

  • Supports Pulse Simulation, Cycle Life, Rate Charging/Discharging, DCIR and dQ/dV

  • Supports SMBus communication

  • Supports Auxiliary Voltage, Auxiliary Temperature and Environmental Test Chambers

  • Optional 0 V discharge for specific safety and destructive testing applications

Description

The NEWARE CT-9000-5V15A is a high-precision battery testing system designed for battery cell characterization where fast response, high sampling frequency, and accurate current control are essential. With a 0–5 V output range, a current range from 0.015 mA to 15 A, 1,000 Hz data recording, and a current response time of ≤150 μs, the system can capture rapid changes in battery behavior and support dynamic testing with high temporal resolution. Its four selectable current ranges provide more precise control across different current levels, while the 400 μs minimum pulse width enables short-duration pulse testing for evaluating battery response under rapidly changing operating conditions. The CT-9000-5V15A supports cycle life, rate charge/discharge, pulse simulation, DCIR, and dQ/dV testing, making it suitable for advanced battery research, battery materials research, and characterization of consumer electronics batteries.

Specifications

Parameter

Specification

Equipment Name

CT-9000 Battery Testing System

Model

CT-9000-5V15A

Voltage Output Range / Channel

Charge: 0–5 V; Discharge: 0–5 V

Minimum Discharge Voltage

0 V

Voltage Accuracy

±0.02% F.S. / range

Voltage Stability

0.01% F.S.

Current Output Range / Channel

0.015 mA–15 A

Current Range 1

0.015–15 mA

Current Range 2

15–150 mA

Current Range 3

150 mA–1.5 A

Current Range 4

1.5–15 A

Current Accuracy

±0.02% F.S.

Current Stability

±0.01% F.S.

Output Power / Channel

75 W

Recording Frequency

1,000 Hz

AD Resolution

16-bit

Current Response Time

≤ 150 μs

Minimum Pulse Width

400 μs

Offline Test Storage

1 GB

Maximum Working Step Time

≤ 365 × 24 h/step

Time Resolution Format

h, min, s, ms

The formal technical table confirms the 0–5 V range, four current ranges, 75 W/channel output, ±0.02% accuracy, ±0.01% stability, and ≤150 μs response time.

Application

  • Battery Cell Research

  • Battery Materials Research

  • Consumer Electronics Battery Testing

  • Coin Cell Testing

  • Pouch Cell Testing

  • Solid-State Battery Research

  • Pulse Characterization

  • DCIR Measurement

  • Cycle-Life Testing

  • Rate Charge/Discharge Testing

  • dQ/dV Analysis

  • Dynamic Battery Characterization

NEWARE specifically lists consumer electronics, coin cells, and pouch cells on the product page, while the CT/CE-9000 series is positioned for advanced battery cell characterization and battery materials research.

bottom of page