MP-SPR NAVI™ 420A Ilves
The 420A ILVES is an ideal solution for molecular interaction studies with small molecules, proteins, lipids, and nanoparticles. Its minimal dead volume and high sensitivity, combined with 4 liquid channels, makes the instrument optimal for these applications.
Quantity
Key Highlights
4 independent fluidic channels for simultaneous measurements on a single sensor
High sensitivity with minimal dead volume for efficient sample utilization
Fully automated operation with 96- and 384-well plates and 6-vial liquid autosampling
Real-time, label-free analysis of molecular interactions
Measures binding affinity and kinetics with high sensitivity
KineticTitration™ for faster affinity and kinetic measurements, particularly for surfaces that are difficult to regenerate
Two wavelengths per measurement channel for detecting layer thickness and conformational changes
Wide angular range of 40°–78°, allowing analysis from small molecules and proteins to nanoparticles and living cells
PureKinetics™ for obtaining true binding kinetics without requiring a reference channel
15–45°C temperature control for controlled measurement conditions
Compatible with organic solvents
Supports a broad range of sensor surfaces, including Au, SiO ₂, CMD, BND, NTA, and regenerable avidin
Description
The MP-SPR Navi™ 420A ILVES is a fully automated, high-sensitivity 4-channel Multi-Parametric Surface Plasmon Resonance (MP-SPR) instrument designed for real-time, label-free analysis of molecular interactions. Its minimal dead volume and four independent fluidic channels make the system well suited for sensitive interaction studies while helping minimize sample consumption. The instrument is particularly suitable for studying interactions involving small molecules, proteins, lipids, nanoparticles, and other biological or surface-active materials. The 420A ILVES combines automated sample handling with two wavelengths per measurement channel, enabling characterization of binding affinity, kinetics, layer thickness, and conformational changes. Its wide angular measurement range also allows measurements across a broad range of sample sizes, from small organic molecules to nanoparticles and living cells. The system supports KineticTitration™, which enables sequential analyte injections at different concentrations without requiring dissociation or regeneration between every concentration step. This can shorten affinity and kinetic measurements, particularly when regeneration of the sensor surface is difficult.
Specifications
Parameter | Specification |
Measurement Principle | Multi-Parametric Surface Plasmon Resonance (MP-SPR) |
Measurement Mode | Real-time, label-free |
Fluidic Channels | 4 |
Autosampler | 96-/384-well plate and 6 vials |
Unattended Operation | Yes |
Sample Requirement | 70 µL partial loop / 300 µL full loop |
Minimum Injected Volume | 50 µL |
Buffer Degasser | Yes |
Syringe Pumps | Yes |
Wavelengths per Measurement Channel | 2 |
Angular Measurement Range | 40°–78° |
Temperature Control | 15–45°C |
Kinetic Titration™ | Yes |
PureKinetics™ | Yes |
Organic Solvent Compatibility | Yes |
Sensor Surfaces | Au, SiO₂, CMD, BND, NTA, regenerable avidin, and other functionalized surfaces |
Kinetics & Affinity Characterization | Yes |
Concentration Analysis | Yes |
Thermodynamic Analysis | Yes |
Living Cell Measurements | Supported |
Application
Molecular Interaction Studies Real-time, label-free characterization of molecular binding, affinity, and kinetics. Small Molecule Research Study interactions between small molecules and proteins, lipids, surfaces, or other biological targets with high sensitivity. Protein & Biopharmaceutical Research Characterize protein–protein, protein–ligand, antibody–antigen, and other biomolecular interactions. Lipid & Membrane Research Investigate interactions involving lipid layers, membrane-related systems, and biomolecular surfaces. BioNavis specifically highlights the 420A ILVES for applications involving lipids and molecular interactions. Nanoparticle Research Analyze nanoparticle–surface and nanoparticle–biomolecule interactions. The 420A ILVES is also one of the BioNavis systems recommended for extracellular vesicle studies, where small sample volumes are particularly useful. Biosensor Development Characterize recognition interactions and functionalized sensor surfaces without fluorescent or radioactive labels. Drug Discovery & Biopharmaceutical Development Evaluate binding affinity and kinetics of drug candidates and biological targets. Biophysics Study molecular binding mechanisms, surface interactions, and conformational changes. Living Cell Research Investigate cell–surface interactions and cellular adhesion using compatible measurement configurations.