top of page

MultiEmStat4

Multi-channel Potentiostat / Galvanostat / Impedance Analyzer

Available with 4, 8, or 12 channels FRA / EIS: 10 μHz up to 200 kHz Potential range: ±3 V (LR) or ±6 V (HR) Max. current: ±30 mA (LR) or ±200 mA (HR)

Version (optional)

Quantity

Description

No Compromises on Productivity and Performance The MultiEmStat4 is a compact Potentiostat, Galvanostat, and optional Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS) with 4, 8, or 12 channels. The MultiEmStat4 comes in two versions; the Low Range version is great for applications that require a low current range down to 1 nA, whereas the High Range version is very suitable for applications that need a maximum current of 200 mA. The MultiEmStat4 is controlled with MultiTrace for Windows, or you can write your own MethodSCRIPT and control it from any platform or operating system.

Specifications

Parameter

MultiEmStat4 LR

MultiEmStat4 HR

Channels

4, 8, or 12

4, 8, or 12

Instrument Type

Potentiostat / Galvanostat / FRA

Potentiostat / Galvanostat / FRA

Potential Range

±3 V

±6 V

Max. Compliance Voltage

±5 V

±8 V

Current Ranges

1 nA–10 mA, 8 ranges

100 nA–100 mA, 7 ranges

Maximum Current

±30 mA

±200 mA

EIS / FRA

Optional

Optional

EIS Frequency

10 µHz–200 kHz

10 µHz–200 kHz

Galvanic Isolation

Optional

Optional

Electrode Connections

WE, RE, CE, Ground

WE, RE, CE, Sense, Ground

Electrode Connector

2 mm banana plugs

2 mm banana plugs

Internal Storage

500 MB/channel

500 MB/channel

Data Capacity

>15 million data points/channel

>15 million data points/channel

Communication

USB Type-B

USB Type-B

Housing

Aluminum

Aluminum

Application

The MultiEmStat4 is particularly suitable for research where multiple electrochemical measurements need to be performed in parallel. Electrochemical Research

  • Cyclic Voltammetry (CV)

  • Linear Sweep Voltammetry (LSV)

  • Differential Pulse Voltammetry (DPV)

  • Square Wave Voltammetry (SWV)

  • Chronoamperometry (CA)

  • Chronopotentiometry (CP)

  • Open Circuit Potential (OCP)

  • Electrochemical Impedance Spectroscopy (EIS)

  • Galvanostatic EIS (GEIS)

Sensors & Biosensors

  • Electrochemical Sensor Development

  • Biosensor Research

  • Sensor Array Testing

  • Parallel Sensor Characterization

  • Electrode Screening

Energy & Materials

  • Battery Research

  • Supercapacitor Research

  • Electrode Characterization

  • Corrosion Studies

  • Materials Electrochemistry

High-Throughput & Parallel Measurements

  • Multiple Electrode Testing

  • Electrode Array Characterization

  • Parallel Electrochemical Experiments

  • Polypotentiostat Measurements

  • Multi-sample Screening

bottom of page