VSP Potentiostat
5 channels - A versatile, research grade, multichannel electrochemical workstation
Quantity
Key Highlights
5-channel modular potentiostat/galvanostat
Up to 5 channels in a single chassis
EIS from 10 µHz to 1 MHz
Current range from ±10 µA to ±1 A depending on channel configuration
Standard VSP maximum current: ±400 mA
Optional 4 A internal current booster
External current boosters available from 2 A up to 100 A
Flexible 2-, 3-, 4-, or 5-electrode configurations
20 V compliance, adjustable from −20 V to +20 V
EC-Lab® software for instrument control and data analysis
Ethernet and USB 2.0 connectivity
Expandable modular architecture for additional channels and options
Description
The BioLogic VSP Potentiostat is a versatile, research-grade multichannel electrochemical workstation built around a modular 5-channel chassis. It can be configured according to different research requirements, with options including Electrochemical Impedance Spectroscopy (EIS), low-current measurements, high-current boosters, and additional potentiostat channels. The VSP supports a wide range of electrochemical experiments, from general electrochemistry and sensors to batteries, energy storage, corrosion, and materials research. Its compatibility with EC-Lab® software provides comprehensive control, measurement, and data analysis capabilities. For applications requiring higher currents, the system can be expanded with an internal 4 A booster or external boosters ranging from 2 A to 100 A, depending on the configuration.
Specifications
Parameter | Specification |
Number of Channels | Up to 5 |
Electrode Connections | 2, 3, 4, or 5 electrodes |
Potentiostat / Galvanostat | Yes |
EIS | 10 µHz – 1 MHz |
EIS Quality Indicators | Yes, with the “e”-type channel board |
Voltage Compliance | 20 V, adjustable from −20 V to +20 V |
Voltage Measurement Ranges | ±2.5 V, ±5 V, ±10 V; ±10 V adjustable |
Voltage Accuracy | < 0.1% FSR |
Voltage Resolution | Down to 76 µV below 10 V |
Current Ranges | ±10 µA to ±1 A, depending on configuration |
Maximum Current | ±1 A; ±400 mA for standard VSP configuration |
Current Accuracy | < 0.1% FSR |
Current Resolution | Down to 760 pA |
Internal Current Booster | Optional 4 A |
External Current Booster | 2 A – 100 A |
Acquisition Time | 20 µs with EC-Lab Express; 200 µs with EC-Lab |
Software | EC-Lab®, EC-Lab Express, EC-Lab Developer Package |
Analog Inputs | 2 |
Analog Output | 1 |
TTL I/O | 3 |
Monitor Outputs | 2 – current and voltage |
Interfaces | Ethernet, USB 2.0 |
Power Requirement | 300 W |
Application
The VSP can be used for a broad range of electrochemical research applications, including:
General Electrochemistry
Electroanalytical Chemistry
Electrochemical Sensors
Battery Research & Testing
Energy Storage
Energy Conversion
Fuel Cells & Electrolyzers
Corrosion Studies
Materials Research
Coatings
Electrochemical Impedance Spectroscopy (EIS)
BioLogic specifically lists the VSP for electroanalytical research, general electrochemistry, corrosion, sensors, energy conversion, energy storage, batteries, and coatings.